The "Dry Air Line" of Paper Mills: How Fabric Ducts Handle High Humidity, Paper Dust and Cross-Machine Moisture Profile

A paper machine hall is a harder environment than it looks. Moisture evaporates continuously from the wet end, while the rewind, slitting and packing areas keep releasing paper dust and lint. In summer the relative humidity stays high for long stretches; in winter some zones swing the other way. For the web itself, an even moisture profile across the machine width decides whether the sheet curls, wrinkles or breaks. For the equipment, condensation dripping and corrosion in a damp hall are slow, persistent costs.

Illustrative image: JVTIADUCT fabric duct system in a paper mill.
Illustrative image: JVTIADUCT fabric duct system in a paper mill.

1. Spreading dry air across the full web width

Differences in cross-machine moisture usually start with uneven air supply. Fabric ducts run lengthwise above the machine and release air through laser-cut perforations along the lower quadrant, so the air leaves at low velocity over a large area instead of arriving as concentrated jets. With several parallel runs, the coverage across the width becomes continuous, and the gap between the two edges and the centre of the web narrows.

2. Condensation and corrosion in a wet hall

The duct wall is woven fabric rather than sheet metal, so it does not collect the cold-surface beads of condensate that a galvanised duct develops when the supply air is much colder than the hall. With permeable discharge, part of the air passes through the wall and spreads before it reaches the sheet or the machine frame, which lowers the risk of water spots. In a damp hall the fabric and its supporting frame also resist corrosion better than plain metal ductwork.

3. Paper dust and cleaning

Paper dust settles on every surface in a mill. Fabric ducts can be taken down section by section for washing, so the lint held inside the run is dealt with directly instead of being left in a fixed metal duct. When a line is rearranged or an extra supply point is needed, flexible sections are also quicker to re-hang than rigid duct.

4. Product and fire considerations

Where even air distribution is the main task, the ventilation type (JT-H) is the usual starting point; where slitting and packing zones need a cleaner air path, the purification type (JT-P) is available; where the duct wall temperature has to stay closer to the supply air, the insulated composite type (JT-T) can be considered; and where the building carries explicit fire requirements, the non-combustible type (JT-N) is the relevant option. These products can be assessed against EN 13501-1, EN 13823, UL 723 and CE.

The duct is only one part of the system. What keeps the web stable is the match between air distribution and the hall's heat and moisture load. Even air and a steady moisture level are what let a paper machine run with fewer breaks and less downgrade.

prev
The "Soft Steady Air" of Textile Mills: How Fabric Ducts Cope with Lint, Static and Yarn Breakage
recommended for you
Get in touch with us

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2026 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service