In electronics and semiconductor plants, cleanliness is a managed number: particle counts, air change rates, room pressure, temperature and humidity, each with an acceptance line. The hard part is rarely getting air into the room. It is spreading a large volume of clean air gently enough. Push the airflow too hard and the particles resting on floors and machine surfaces are lifted back into the working zone.
Illustrative image: JVTIADUCT fabric duct system in an electronics cleanroom.
1. High air change rates without the disturbance
Conventional diffusers concentrate treated air into a few high-velocity jets. Those jets entrain room air along the way and tend to form eddies near the working level. A fabric duct releases air through rows of laser-cut perforations along its length, at low discharge velocity and over a very large area, so the room can be turned over often while air speed at the working zone stays gentle.
2. A wall that does not collect dust, and can be washed
Cleanrooms suffer most from surfaces that hide contamination. The duct wall is woven polyester with no diffuser blades or exposed insulation to collect dust, and sections can be taken down, washed and re-hung when needed, without a long shutdown just to clean the ductwork.
3. Condensation under low-temperature supply
Clean zones are kept cold all year, and supply air is colder still, so the outside of metal ductwork tends to run wet; a drip lands directly on product or floor. With permeable discharge, air passes through the fabric wall and mixes at the surface, which keeps the wall closer to room temperature. Where the risk is high, the insulated composite type (JT-T) helps hold the wall temperature above dew point.
4. Humidity, static and line changes
Stable humidity is the precondition for static control. Running continuously along the length of the hall, a fabric duct distributes supply air fairly evenly, narrowing the gap between an over-cooled near end and a dry far end. When a line is rearranged or a machine is added, flexible sections are quicker to re-route or extend than rigid duct.
For electronics cleanrooms the purification type (JT-P) is the usual starting point, JT-T where insulation is needed, JT-N non-combustible where the building carries explicit fire requirements, and JT-H for general ventilation duty. These products can be assessed against EN 13501-1, EN 13823, UL 723 and CE.
In the end, cleanroom air quality shows up as yield and maintenance cost. Getting the air even and the disturbance low is the part that actually takes engineering.